image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Hotel Info 
 Abstracts 
 Scientific Program 
 Exhibition 
 Contact Us 
 Personal page 
 Photo and Film Festival 
       XXVI Annual Congress of the Iranian Society of Ophthalmology        بـیــست و ششمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Effect of donor graft thickness on clinical outcomes after Descemet stripping automated endothelial keratoplasty
Author(s): Sepehr Feizi, Mohammad Ali Javadi, Roya Jafari
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Sepehr Feizi
Affiliation :(optional) Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences
E mail: sepehrfeizi@yahoo.com
Phone: 22546393
Mobile: 09122837429
Purpose:

To evaluate the effects of donor graft thickness on postoperative best spectacle-corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet stripping automated endothelial keratoplasty (DSAEK).

Methods:

This retrospective, interventional case series enrolled 77 eyes of 64 patients who underwent DSAEK with or without simultaneous cataract surgery. Clinical outcomes, including BSCVA, spherical equivalent refraction, keratometric astigmatism, IOP, and ECD were assessed at the final follow-up examination. Univariate analyses were used to investigate the effects of postoperative donor graft thickness on clinical outcomes and complications.

Results:

The mean patient age was 62.3±15.6 years old, and the patients were followed for 26.2±20.9 months postoperatively. The mean donor age was 30.4±11.2 years old, and the mean preoperative ECD was 3127.4±315.1 cells/mm2, which decreased to 1788.6±716.5 cells/mm2 postoperatively (P<0.001). The mean postoperative central graft thickness was 102.4±31.6 µm. In the univariate analysis, postoperative central graft thickness was significantly associated with postoperative IOP (r=0.42, P=0.005), central recipient thickness (r=-0.46, P=0.002), and ECD (r=0.36, P=0.016). No significant association was found for central graft thickness with postoperative BSCVA (P=0.70), spherical equivalent refraction (P=0.33), keratometric astigmatism (P=0.27), graft detachment (P=0.16), graft decentration (P=0.17), high IOP (P=0.53), or endothelial rejection (P=0.88).

Conclusion:

This study failed to demonstrate any significant correlation between graft thickness and BSCVA. Attempting to minimize graft thickness might not have the desired outcome with regard to endothelial cell density and function. Increased graft thickness could negatively impact the accuracy of IOP measurements after DSAEK.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label