       XXVI Annual Congress of the Iranian Society of Ophthalmology        بـیــست و ششمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Long-term Outcomes and Complications of Posterior Chamber Phakic Intraocular Lens Implantation for the Correction of High Myopia and Astigmatism in keratoconic patients (5 Years Study)
Author(s): Seyed Javad Hashemian, MD • Mohammad Ebrahim Jafari, MD
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Seyed javad Hashemian
Affiliation :(optional) Eye research center, Rassoul Akram hospital, Iran University of Medical Sciences and Iranian Eye Clinic, Tehran, IRAN
E mail: sj_hashemian@yahoo.com
Phone: 22583455
Mobile: 09121142168
Purpose:

The aim was to evaluate the long-term safety, efficacy, stability and predictability of posterior chamber phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus.

Methods:

Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, and adverse effects were evaluated in 23 keratoconic eyes of 13 patients after 5 years with Visian ICMV4 pIOL (STAAR Surgical Inc.).

Results:

The mean pre-operative spherical equivalent (SE) and cylinder changed from -5.35  2.82 diopters (D) and -3.14 1.58 D to -.78  1.31 D and -1.56  1.53 D, respectively 5 years postoperatively. Before the surgery the mean Snellen decimal CDVA was .60  0.20. The mean UDVA and CDVA changed to 0.74  0.22 and 0.88  0.16, respectively. 82.5% of eyes achieved 20/40 or better UDVA postoperatively. The mean safety and efficacy indices were 1.47  0.32 and 1.24  0.34, respectively. No eye lost a line of visual acuity and 19 eyes gained one or more lines. 11% Endothelial cell loose was occurred. No significant changes in intraocular pressure, steep, flat and mean keratometry was seen during the study. Crystalline lens was clear.

Conclusion:

The clinical outcomes of the current study demonstrate the safety, efficacy and predictability of toric implantable collamer lens in the correction of myopia and myopic astigmatism associated with keratoconus. The patients’ refractions achieved early stability and remained stable during the course of the study.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو کنگره سالهای گذشته
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits
Find us on Social Media
Congress Count Down
Today Label
Last Month Label
Total Visitors Label